navigasi

Jumat, Agustus 07, 2015

Cara memasang RJ45 serta PIN OUT RJ45 , Teori Dasar RJ45

 RJ45 Wiring Standards

T568A and T568B are the two color codes used for wiring eight-position RJ45 modular plugs. Both are allowed under the ANSI/TIA/EIA wiring standards. The only difference between the two color codes is that the orange and green pairs are interchanged. T568A wiring pattern is recognized as the preferred wiring pattern for this standard because it provides backward compatibility to both one pair and two pair USOC wiring schemes. The T568B standard matches the older ATA&T 258A color code and is/was(?) the most widely used wiring scheme. It is also permitted by the ANSI/TIA/EIA standard, but it provides only a single pair backward compatibility to the USOC wiring scheme. The U.S. Government requires the use of the preferred T568A standard for wiring done under federal contracts.

T568A Wiring Standard

Pin #12345678
 Wire Color RJ45 WiringRJ45 WiringRJ45 WiringRJ45 WiringRJ45 WiringRJ45 WiringRJ45 WiringRJ45 Wiring

T568B Wiring Standard

Pin #12345678
 Wire Color RJ45 WiringRJ45 WiringRJ45 WiringRJ45 WiringRJ45 WiringRJ45 WiringRJ45 WiringRJ45 Wiring

RJ45 to RJ45 Cable Pinouts

Straight Through Cable
RJ45 RJ45
Pin #Connects ToPin #
1<-------->1
2<-------->2
3<-------->3
4<-------->4
5<-------->5
6<-------->6
7<-------->7
8<-------->8
 
Crossover Cable
RJ45 RJ45
Pin #Connects ToPin #
1<-------->3
2<-------->6
3<-------->1
4<-------->7
5<-------->8
6<-------->2
7<-------->4
8<-------->5
 
Rollover Cable
RJ45 RJ45
Pin #Connects ToPin #
1<-------->8
2<-------->7
3<-------->6
4<-------->5
5<-------->4
6<-------->3
7<-------->2
8<-------->1